概况:
卧式吊顶机BGG-D特点: 1.风量1000-10000m3/h 2.冷量 回风工况:5.5KW~74.4KW 3.新风工况: 9.8KW~139.6KW 4.热量 回风工况: 8.8LW~117.6KW 5.新风工况: 17KW~160KW 6.安装于吊顶内,高度小于670mm, 卧式吊顶机BGG-D用途: 用于商场、影视厅、银行、宾馆等场合,作一般空调送风或新风系统 一、BGG-WD卧式吊顶空调机组技术性能参数表: | 风量 (m/h) | 余压 (Pa) | 冷量 (KW) | 热量 (KW) | 水量 (T/h) | 水阻 (KPa) | 功率 (KW) | 噪声 DB(A) | 重量 (Kg) | 回风 工况 | 新风工况 | 回风 工况 | 新风工况 | 回风 工况 | 新风工况 | 回风 工况 | 新风 工况 | BGG-12WD | 1200 | 180 | 7.2 | 13.1 | 11.6 | 15.2 | 1.23 | 2.2 | 2.1 | 4.1 | 0.25 | 54 | 80 | BGG-12XWD | 150 | 9.5 | 17.8 | 13.5 | 18.4 | 1.62 | 3.05 | 3.3 | 6.5 | 85 | BGG-15WD | 1500 | 180 | 9.1 | 16.2 | 14.5 | 18.9 | 1.57 | 2.8 | 2.5 | 5.8 | 0.32 | 55 | 98 | BGG-15XWD | 150 | 12.2 | 22.2 | 16.6 | 22.8 | 2.07 | 3.83 | 3.7 | 7.6 | 109 | BGG-20WD | 2000 | 200 | 11.9 | 21.4 | 19.2 | 25.2 | 2.1 | 3.67 | 3.5 | 6.5 | 0.37 | 55 | 115 | BGG-20XWD | 160 | 15.3 | 29.5 | 23.5 | 30.4 | 2.77 | 5.1 | 4.3 | 8.9 | 126 | BGG-30WD | 3000 | 230 | 17 | 32.4 | 29.2 | 37.8 | 3.12 | 5.55 | 5.6 | 9.5 | 0.55 | 56 | 149 | BGG-30XWD | 190 | 22.1 | 44.6 | 33.3 | 45.7 | 4.14 | 7.8 | 6.2 | 10.5 | 161 | BGG-35WD | 3500 | 200 | 19.4 | 37.7 | 33.9 | 45.2 | 4.15 | 7.8 | 6.2 | 10.4 | 0.32X2 | 57 | 154 | BGG-35XWD | 160 | 25.7 | 51.4 | 40 | 53.2 | 4.85 | 8.9 | 9.5 | 14.6 | 169 | BGG-40WD | 4000 | 200 | 22 | 42.3 | 38.5 | 50.3 | 4.16 | 7.34 | 9.4 | 17.5 | 0.37X2 | 58 | 166 | BGG-40XWD | 160 | 29.3 | 58.8 | 46.9 | 61.2 | 5.55 | 10.2 | 10.5 | 20 | 185 | BGG-45WD | 4500 | 220 | 24.5 | 48.1 | 43.3 | 56.5 | 4.67 | 8.2 | 10.7 | 19.4 | 0.45X2 | 58 | 175 | BGG-45XWD | 180 | 32.6 | 66.5 | 52.8 | 68.5 | 6.25 | 11.5 | 12.5 | 23.5 | 191 | BGG-50WD | 5000 | 220 | 26.8 | 53.4 | 48.2 | 62.9 | 5.17 | 9.12 | 11.5 | 21.4 | 0.45X2 | 59 | 183 | BGG-50XWD | 180 | 36.5 | 73.9 | 58.5 | 76 | 7.0 | 12.7 | 13.5 | 26.4 | 198 | BGG-60WD | 6000 | 230 | 32.6 | 64.6 | 58 | 75.4 | 6.23 | 11.1 | 14.5 | 28.3 | 0.55X2 | 60 | 196 | BGG-60XWD | 190 | 44.2 | 88.9 | 66.5 | 91.3 | 8.29 | 15.3 | 19.4 | 32.4 | 218 | BGG-70WD | 7000 | 280 | 38.3 | 72.4 | 68.5 | 87.9 | 7.26 | 13 | 16.2 | 26.4 | 0.75X2 | 61 | 208 | BGG-70XWD | 240 | 49.1 | 101 | 75.8 | 106 | 9.36 | 17.9 | 20.5 | 38.7 | 242 | BGG-80WD | 8000 | 300 | 43.4 | 82.7 | 78.3 | 101 | 8.3 | 20.9 | 18.5 | 28.2 | 0.75X2 | 61 | 232 | BGG-80XWD | 260 | 56.2 | 115 | 86.5 | 122 | 10.8 | 20.3 | 22.7 | 38 | 265 | BGG-90WD | 9000 | 360 | 49.3 | 96.3 | 86.7 | 113 | 9.34 | 16.5 | 19.5 | 32.7 | 1.1X2 | 62 | 246 | BGG-90XWD | 320 | 66.8 | 133 | 105 | 137 | 12.5 | 22.9 | 24.6 | 39.6 | 272 | BGG-100WD | 10000 | 500 | 54.6 | 107 | 96.4 | 126 | 10.4 | 18.4 | 21.4 | 38.4 | 1.5X2 | 63 | 268 | BGG-100XWD | 460 | 72.5 | 148 | 117 | 151 | 13 | 25.5 | 26.8 | 43.6 | 282 | BGG-120WD | 12000 | 500 | 66.4 | 129 | 116 | 151 | 13.8 | 22.1 | 24.6 | 42.1 | 1.8X2 | 64 | 289 | BGG-120XWD | 460 | 87.9 | 178 | 133 | 182 | 16.8 | 26 | 28.7 | 48.7 | 325 | 注:1.回风工况:供冷进风干球温度27℃,湿球温度19.5℃,进水温度7℃,进出水温度差5℃。 供热进风干球温度15℃,热水进水温度60℃。 2.新风工况:供冷进风干球温度34℃,湿球温度28℃,进水温度7℃,进出水温差5℃。 供热进风干球温度-4℃,热水进水温度60℃。 |